TRAINING.

Fire Alarm Systems: Design, Installation, Inspection and Testing

Ottawa, Ontario /
Feb 19 - 21, 2019 /
Course Code: 09-1119-2357

REGISTER NOW
The confirmation of a course and venue depends on early registration; Register early to avoid the postponement or cancellation of a course.
  • Overview
  • Syllabus
  • Instructor
  • Location

Overview

After Participating in this course, you will be able to:

  • Describe the types of fire alarm systems and their applications
  • Recognize the basic and optional features of fire alarm systems
  • Explain the requirements of Voice Communication Systems
  • Relate the requirements of Province of Ontario building and fire code requirements to systems
  • Apply your knowledge to design a fire alarm system

Description
Only a well-designed and functioning fire alarm system can protect people and the building from a fire hazard. This course is designed to provide participants with the tools needed to design, install and maintain fire alarm systems in accordance with building and fire codes.

Course Outline

  • Categories and types of fire alarm systems
  • Functions of fire alarm systems
  • Features of fire alarm systems
  • Types of detection devices
  • Analysis of ULC Standards
  • Types of air sampling applications
  • Audible signaling devices and ancillary systems
  • Province of Ontario Building code and fire code requirements

Who Should Attend
Fire Alarm System Designers and Engineers • Installation and Service personnel • Electrical Project Engineers and Supervisors • Building Owners • Property Managers • Superintendents • Maintenance personnel • Building and Fire Inspectors

More Information

Syllabus

Daily Schedule
8:00 Registration & Coffee (Day 1 only)
8:30 Seminar begins
12:00 Lunch (provided)
4:30 Adjournment

There is an one‐hour lunch break each day in addition to a refreshments and networking break each morning and afternoon. Lunch and refreshments are provided.

Day I

Overview of Fire Alarm Systems and Applications

  • Input, output, processing, response time, and annunciation
  • Stand-alone
  • Distributed
  • Centralized
  • Networking (local and degraded mode)

Categories and Types of Fire Alarm Systems

  • Local, auxiliary, remote, and proprietary
  • Conventional and addressable (analog and digital)
  • Single-stage and two-stage systems
  • Single- to three-channel voice communication
  • Fire fighters telephone, indication, and paging

Standard and Optional Features of Fire Alarm Control Units

  • Basic features, annunciation, and controls
  • Electrical supervision
  • Priority level of indication
  • Alarm silence/inhibit
  • Input/output mapping
  • Requirement of annunciation (local and remote)
  • Circuit types Class A and B
  • Conventional and addressable loops
  • Response time
  • Different types of faults and trouble
  • Optional features such as suppression systems, alarm verification, voice, smoke control, and egress
  • door securing

Compatibility of Input/Output Devices, Voice Communication Systems

  • Initiating and signaling devices
  • Interfacing voice systems, built-in and stand-alone
  • Interfacing different makes of control units

Evaluation and Certification of Fire Alarm Equipment as Per ULC Standards

  • How ULC evaluates and certifies control units according to CAN/ULC-S527
  • Certification of field devices according to their respective CAN/ULC-500 series standards
  • What is required in voice communication systems
  • Evaluation of transponders and their role
  • Primary and secondary power requirements

In-Depth Analysis of National Installation and Maintenance Standards

  • CAN/ULC-S524 Standard for Installation of Fire Alarm Systems
  • CAN/ULC-S536 Standard for Inspection and Testing of Fire Alarm Systems
  • CAN/ULC-S537 Standard for Verification of Fire Alarms

Day II

Maintenance of Fire Alarm Systems and Access Level

  • What level of access may be made available to the building owners/users and service companies
  • (software controlled)
  • Role of AHJ
  • Responsibilities of the manufacturer

Automatic Sprinkler Systems

  • Requirements for sprinkler flow alarms
  • Types of flow alarms
  • Requirements for sprinkler supervision

ULC Certificate Program and Starting a Listed Service Company

  • Requirements and how to qualify for certificates
  • How you can start and become a listed fire alarm service company
  • Required qualification and experience

Ontario Fire Code

  • What is required for fire alarm system and restorations
  • Testing and maintenance

Customized Installation and Special Inspection

  • How customized installation affects ULC certification
  • What is required for special inspection
  • Who can initiate the request for field inspection
  • AHJ involvement and their requirements for issuing occupancy permits

Exercise

  • Design of a fire alarm system for a Low Rise building

Day III

Types of Detection Devices

  • Heat Detectors: types; spacing and placement restrictions as per ULC S524
  • Smoke Detectors: types; spacing and placement restrictions
  • Flame Detectors: types; spacing and placement restrictions
  • Air Duct Type Smoke Detectors: types; spacing and placement restrictions
  • Manual Stations: types and location requirements

VESDA Air Sampling Applications

  • Overview of the purpose and type of areas protected by VESDA systems

Types of Audible Signaling Devices

  • Bells; horns and speakers: types and location requirements as per the National  Building Code
  • Audibility level requirements as per the National Building Code

Types of Ancillary Systems connected to Fire Alarm Systems

  • Electromagnetic locking devices (maglocks)
  • Hold Open devices

Exercise

  • Design of a fire alarm system for a High Rise building

Workshop: Design/Layout of a Typical Fire Alarm System
Participants will have an opportunity to design a fire alarm system based on the knowledge gained from the course.

Inspection Checklist
An initial checklist will be provided and discussed. Participants will be able to keep the completed checklist for future reference

Instructor

John Percy, CFAA Tech, PFLSE, CFEI

John Percy is a certified Canadian Fire Alarm Association Technician (CFAA) for Ontario, certified public fire and life safety officer, public information and fire prevention officer and training facilitator with the Office of the Fire Marshal and Emergency Management.



Venue

To be announced

Although the venue is not officially confirmed, EPIC courses are generally held at the following location(s):

Hilton Garden Inn Ottawa Airport
2400 Alert Road
Ottawa ON  K1V 1S1

Please confirm with EPIC that the venue has been officially confirmed before making any reservations or travel arrangements.

REGISTER NOW
NOT INTERESTED IN THIS COURSE?

We always want to improve the quality of our courses. Please select any reasons why you feel this course is inadequate (check all that apply).

Please check this box:
Course Rating
4.6 out of 5

Overall rating of this course by its previous attendees!

Fee & Credits
  • 2.1 Continuing Education Units (CEUs)
  • 21 Professional Development Hours (PDHs)
Early Registration Fee:

$2095 + taxes

Fee after January 11, 2019:

$2195 + taxes

Register




On-Site Training
This course can be customized and delivered to your group of staff at your facility, saving time and money.
REQUEST A QUOTE
OTHER LOCATIONS
E-Newsletter
EPIC's email newsletter is a great source of information for:

  • course updates
  • surveys
  • informative articles/papers
  • exclusive discounts
Subscribe
Top